| Sign In | Join Free | My spintoband.com |
|
Brand Name : ESEGAS
Model Number : ESE-LASER-100
MOQ : 1 unit
Payment Terms : T/T
Delivery Time : 14 working days
Name : TDLAS Laser Gas Analyser
Response time (T90) : ≤30s
Digital communication : RS485/RS232/GPRS
Power : 100VAC ~ 240VAC
Repeatability : ≤1%
Analog output : 4-20mA output (isolation, maximum load 750Ω)
Principle : Tunable Diode Laser Absorption Spectroscopy (TDLAS) Technology
Laser Gas Analyzers TDLAS technology 19 inch NH3/HCL/HF/H2S/CO/CO2/O2
Here are some key points about laser gas analyzers:
- Utilize laser light absorption spectroscopy to identify and measure gases. Very selective and sensitive.
- Tunable diode laser absorption spectroscopy (TDLAS) is the most common technique used.
- Lasers are tuned to a specific wavelength absorbed by the target gas molecules. The gas concentration is proportional to the measured absorption.
- Can detect trace gases at very low ppm or ppb levels. Detection limits down to ppb or even ppt levels.
- Extremely fast response times, on the order of seconds or fractions of seconds. Allows real-time measurement.
- Capable of in situ or extractive measurements. Can be used for remote sensing over distances.
- Measurements not affected by temperature or pressure changes. Stable and drift-free operation.
- Common gases analyzed include CO, CO2, CH4, NH3, H2O, HF, O2, HCl. Useful for toxic and flammable gases.
- Applications include industrial process control, environmental gas monitoring, semiconductor manufacturing, combustion optimization.
- Avoid interference from other gases by using multi-line or wideband laser techniques.
- Require periodic calibration using known concentration gas cells.
In summary, laser gas analyzers provide fast, accurate, and selective trace gas measurements for critical monitoring applications across many industries.
ESE-LASER-200 Laser Gas Analyser is a 19" 4U TDLAS gas analyzer for industrial online analysis .The gas analyzer combine multiple reflection long optical path technology that can analysis gas including NH3,HCL,HF,CH4,H2S,CO,CO2,O2 .
Specifiications
| Linearity Error | ≤±1%FS |
| Repeatability | ≤±1% |
| Zero Drift | ≤±1%FS/half year |
| Span Drift | ≤±1%FS/half year |
| Calibration Cycle | ≤2 times/year |
| Response time | ≤30S |
| Interface Signal | |
| Analog Output | 2*4-20mA output |
| Analog Input | 2*4-20mA output |
| Digital Output | RS485/RS232/GPRS |
| Relay Output | 3(24V,1A) |
| Operating Conditions | |
| Power Supply | 100VAC-240VAC |
| Purge Gas | 0.3Mpa-0.8Mpa |
| Ambient Temperature | ’-20℃-+60℃ |
|
|
TDLAS Laser Gas Analyser 100VAC-240VAC For Semiconductor Manufacturing Images |